Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
J Appl Physiol (1985) ; 135(5): 977-984, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37675475

RESUMO

CO2 inhalation has been previously reported as a treatment for central sleep apnea both when associated with heart failure or where the cause is unknown. Here, we evaluated a novel CO2 supply system using a novel open mask capable of comfortably delivering a constantly inspired fraction of CO2 ([Formula: see text]) during sleep. We recruited 18 patients with central sleep apnea (13 patients with cardiac disease, and 5 patients idiopathic) diagnosed by diaphragm electromyogram (EMG) recordings made during overnight full polysomnography (PSG) (night 1). In each case, the optimal [Formula: see text] was determined by an overnight manual titration with PSG (night 2). Titration commenced at 1% CO2 and increased by 0.2% increments until central sleep apnea (CSA) disappeared. Patients were then treated on the third night (night 3) with the lowest therapeutically effective concentration of CO2 derived from night 2. Comparing night 1 and night 3, both apnea-hypopnea index (AHI; 31 ± 14 vs. 6 ± 3 events/h, P < 0.01) and arousal index (22 ± 8 vs. 15 ± 8 events/h, P < 0.01) were significantly improved during CO2 treatment. Sleep efficiency improved from 71 ± 18 to 80 ± 11%, P < 0.05, and sleep latency was shorter (23 ± 18 vs. 10 ± 10 min, P < 0.01). Heart rate was not different between night 1 and night 3. Our data confirm the feasibility of our CO2 delivery system and indicate that individually titrated CO2 supplementation with a novel device including a special open mask can reduce sleep disordered breathing severity and improve sleep quality. Randomized controlled studies should now be undertaken to assess therapeutic benefit for patients with CSA.NEW & NOTEWORTHY A novel device using a special mask was developed and proved that CO2 therapy using the device could eliminate central sleep apnea (CSA) events and improve sleep quality including reducing arousal index in patients with heart failure. The device would become a useful clinical treatment for heart failure patients with CSA.


Assuntos
Insuficiência Cardíaca , Apneia do Sono Tipo Central , Humanos , Dióxido de Carbono , Sono , Pressão Positiva Contínua nas Vias Aéreas , Insuficiência Cardíaca/tratamento farmacológico
2.
Sleep Breath ; 27(6): 2351-2359, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37211583

RESUMO

PURPOSE: CPAP is the "gold standard" treatment for obstructive sleep apnea (OSA). Current CPAP models have developed additional functions including automatic CPAP and pressure relief. However, CPAP adherence has not improved over the last three decades. Many patients in low-income countries cannot afford these CPAP devices. A novel simple CPAP device with a fixed pressure without pressure controller was developed. METHODS: Manual CPAP pressure titration was performed in 127 patients with OSA. Six patients with a titration pressure higher than 11 cmH2O and 14 patients who could not tolerate CPAP were excluded, leaving 107 participating in the following 2 studies. In study one, 54 of 107 patients were treated by both conventional fixed CPAP and simple CPAP in random order. In the second study, another 53 patients were treated by both autoCPAP in automatic function and simple CPAP in random order. Simple CPAP was fixed at 10 cmH2O, 8 cmH2O, and 6 cmH2O for patients whose titration pressure was between 9-10, 7-8, and ≤ 6 cmH2O, respectively. Conventional fixed CPAP device was set exactly the same as manual titration pressure. RESULTS: All patients whose manual titration pressure ≤ 10 cmH2O were effectively treated by simple CPAP (AHI 40.7 ± 2.3 events/h before vs 2.5 ± 0.3 events/h after, p < 0.001). Patients expressed similar preferences for simple CPAP, autoCPAP, and conventional fixed CPAP (p > 0.05). CONCLUSIONS: We conclude that a novel simple CPAP is an alternative treatment for most patients with OSA, which may widen access to CPAP therapy in the developing countries because of its low cost.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Polissonografia , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas
4.
J Appl Physiol (1985) ; 128(3): 586-595, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31944886

RESUMO

Approximately 20% of chronic obstructive pulmonary disease (COPD) patients have been considered to have a "nonhyperinflator phenotype." However, this judgment depends on patients making a fully maximal inspiratory capacity (IC) maneuver at rest, since the IC during exercise is compared with this baseline measurement. We hypothesized that IC maneuvers at rest are sometimes submaximal and tested this hypothesis by measuring IC and associated neural respiratory drive at rest and during inhalation of CO2 and exercise in patients with COPD. Twenty-six COPD patients [age 66 ± 6 yr, mean forced expiratory volume in 1 s (FEV1) 40 ± 11% predicted] and 39 healthy subjects (age 39 ± 14 yr, FEV1 98 ± 12% predicted) were studied. IC and the diaphragm electromyogram (EMGdi) associated with it (EMGdi-IC) and forced inspiratory vital capacity (FIVC) and its corresponding EMGdi (EMGdi-FIVC) were measured during inhalation of 8% CO2 (8% CO2-92% O2) and room air. Incremental exhaustive cycle ergometer exercise was also performed in both patients with COPD and healthy subjects. IC, EMGdi-IC, FIVC, and EMGdi-FIVC during breathing 8% CO2 were significantly greater than those during breathing room air in both patients with COPD and healthy subjects (all P < 0.001). EMGdi-IC in patients with COPD constantly increased during exercise from 145 ± 40 µV at rest to 185 ± 52 µV at the end of exercise but change in IC was variable. Neural respiratory drive and its relevant IC increased during hypercapnia. Exercise-related hypercapnia in patients with COPD raises neural respiratory drives, which compensate for IC reduction, leading to underestimation of dynamic hyperinflation measured by IC at rest breathing room air.NEW & NOTEWORTHY Inspiratory capacity measured during hypercapnia is higher than that during eucapnia. Thus total lung capacity is not always be achieved by a standard inspiratory capacity maneuver, leading to risk of underestimation of dynamic hyperinflation in patients with severe chronic obstructive pulmonary disease after exhaustive exercise.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Adulto , Idoso , Teste de Esforço , Volume Expiratório Forçado , Humanos , Capacidade Inspiratória , Pessoa de Meia-Idade , Fenótipo , Testes de Função Respiratória
5.
J Thorac Dis ; 11(10): 4188-4196, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31737302

RESUMO

BACKGROUND: Prone position ventilation (PPV) is an important strategy for patients with severe acute respiratory distress syndrome (ARDS). This prospective study investigated the use of electromyography of the diaphragm (EMGdi) for monitoring respiratory drive in patients with moderate to severe ARDS during long-term PPV. METHODS: An integrated nostril-gastric feeding tube containing an esophageal electrode and balloon was placed in 14 patients with severe ARDS prior to PPV. EMGdi and trans-pulmonary pressure (∆PL) data were collected before PPV (baseline), every 2 h during PPV, and 2 h after the restoration of supine position ventilation (post-2 h SPV). RESULTS: In ARDS patients, the static compliance of the chest wall was significantly decreased after PPV. EMGdi levels were slightly lower in the early, middle, and late stages of PPV compared with baseline. Patients who received neuromuscular blocker experienced a greater drop in EMGdi from baseline than those who did not. CONCLUSIONS: For ARDS patients, EMGdi was slightly decreased after prolonged PPV. This is contrary to the change in diaphragm electromyography during normal body position changes. Monitoring EMGdi regularly during PPV in ARDS patients is feasible and can be used as a reference for lung protective ventilation strategies.

6.
Eur Respir J ; 53(6)2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30956204

RESUMO

Assessing respiratory mechanics and muscle function is critical for both clinical practice and research purposes. Several methodological developments over the past two decades have enhanced our understanding of respiratory muscle function and responses to interventions across the spectrum of health and disease. They are especially useful in diagnosing, phenotyping and assessing treatment efficacy in patients with respiratory symptoms and neuromuscular diseases. Considerable research has been undertaken over the past 17 years, since the publication of the previous American Thoracic Society (ATS)/European Respiratory Society (ERS) statement on respiratory muscle testing in 2002. Key advances have been made in the field of mechanics of breathing, respiratory muscle neurophysiology (electromyography, electroencephalography and transcranial magnetic stimulation) and on respiratory muscle imaging (ultrasound, optoelectronic plethysmography and structured light plethysmography). Accordingly, this ERS task force reviewed the field of respiratory muscle testing in health and disease, with particular reference to data obtained since the previous ATS/ERS statement. It summarises the most recent scientific and methodological developments regarding respiratory mechanics and respiratory muscle assessment by addressing the validity, precision, reproducibility, prognostic value and responsiveness to interventions of various methods. A particular emphasis is placed on assessment during exercise, which is a useful condition to stress the respiratory system.


Assuntos
Força Muscular , Mecânica Respiratória , Músculos Respiratórios/diagnóstico por imagem , Músculos Respiratórios/fisiologia , Eletromiografia , Europa (Continente) , Exercício Físico , Humanos , Testes de Função Respiratória , Músculos Respiratórios/anatomia & histologia , Descanso , Sociedades Médicas , Estimulação Magnética Transcraniana
7.
Chest ; 154(3): 731-732, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30195366
8.
Chest ; 154(3): 733-734, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30195368
9.
Chest ; 153(5): 1116-1124, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29625777

RESUMO

BACKGROUND: In COPD, functional status is improved by pulmonary rehabilitation (PR) but requires specific facilities. Tai Chi, which combines psychological treatment and physical exercise and requires no special equipment, is widely practiced in China and is becoming increasingly popular in the rest of the world. We hypothesized that Tai Chi is equivalent (ie, difference less than ±4 St. George's Respiratory Questionnaire [SGRQ] points) to PR. METHODS: A total of 120 patients (mean FEV1, 1.11 ± 0.42 L; 43.6% predicted) bronchodilator-naive patients were studied. Two weeks after starting indacaterol 150 µg once daily, they randomly received either standard PR thrice weekly or group Tai Chi five times weekly, for 12 weeks. The primary end point was change in SGRQ prior to and following the exercise intervention; measurements were also made 12 weeks after the end of the intervention. RESULTS: The between-group difference for SGRQ at the end of the exercise interventions was -0.48 (95% CI PR vs Tai Chi, -3.6 to 2.6; P = .76), excluding a difference exceeding the minimal clinically important difference. Twelve weeks later, the between-group difference for SGRQ was 4.5 (95% CI, 1.9 to 7.0; P < .001), favoring Tai Chi. Similar trends were observed for 6-min walk distance; no change in FEV1 was observed. CONCLUSIONS: Tai Chi is equivalent to PR for improving SGRQ in COPD. Twelve weeks after exercise cessation, a clinically significant difference in SGRQ emerged favoring Tai Chi. Tai Chi is an appropriate substitute for PR. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT02665130; URL: www.clinicaltrials.gov.


Assuntos
Terapia por Exercício , Doença Pulmonar Obstrutiva Crônica/reabilitação , Tai Chi Chuan , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Força Muscular , Testes de Função Respiratória , Inquéritos e Questionários , Resultado do Tratamento
10.
Autophagy ; 14(4): 598-618, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29369001

RESUMO

The mechanisms underlying the functional link between autophagy and plant innate immunity remain largely unknown. In this study, we investigated the autophagy-mediated plant defense responses against Verticillium dahliae (V. dahliae) infection by comparative proteomics and cellular analyses. An assessment of the autophagy activity and disease development showed that autophagic processes were tightly related to the tolerance of Arabidopsis plant to Verticillium wilt. An isobaric tags for relative and absolute quantification (iTRAQ)-based proteomics analysis was performed, and we identified a total of 780 differentially accumulated proteins (DAPs) between wild-type and mutant atg10-1 Arabidopsis plants upon V. dahliae infection, of which, 193 ATG8-family-interacting proteins were identified in silico and their associations with autophagy were verified for several selected proteins. Three important aspects of autophagy-mediated defense against V. dahliae infection were revealed: 1) autophagy is required for the activation of upstream defense responses; 2) autophagy-mediated mitochondrial degradation (mitophagy) occurs and is an important player in the defense process; and 3) autophagy promotes the transdifferentiation of perivascular cells and the formation of xylem hyperplasia, which are crucial for protection against this vascular disease. Together, our results provide several novel insights for understanding the functional association between autophagy and plant immune responses.


Assuntos
Arabidopsis/imunologia , Arabidopsis/microbiologia , Autofagia/imunologia , Doenças das Plantas/microbiologia , Verticillium/metabolismo , Regulação da Expressão Gênica de Plantas/imunologia , Proteínas de Plantas/metabolismo , Proteômica/métodos
11.
J Appl Physiol (1985) ; 124(2): 356-363, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29097629

RESUMO

Exercise-induced laryngeal obstruction (EILO), a phenomenon in which the larynx closes inappropriately during physical activity, is a prevalent cause of exertional dyspnea in young individuals. The physiological ventilatory impact of EILO and its relationship to dyspnea are poorly understood. The objective of this study was to evaluate exercise-related changes in laryngeal aperture on ventilation, pulmonary mechanics, and respiratory neural drive. We prospectively evaluated 12 subjects (6 with EILO and 6 healthy age- and gender-matched controls). Subjects underwent baseline spirometry and a symptom-limited incremental exercise test with simultaneous and synchronized recording of endoscopic video and gastric, esophageal, and transdiaphragmatic pressures, diaphragm electromyography, and respiratory airflow. The EILO and control groups had similar peak work rates and minute ventilation (V̇e) (work rate: 227 ± 35 vs. 237 ± 35 W; V̇e: 103 ± 20 vs. 98 ± 23 l/min; P > 0.05). At submaximal work rates (140-240 W), subjects with EILO demonstrated increased work of breathing ( P < 0.05) and respiratory neural drive ( P < 0.05), developing in close temporal association with onset of endoscopic evidence of laryngeal closure ( P < 0.05). Unexpectedly, a ventilatory increase ( P < 0.05), driven by augmented tidal volume ( P < 0.05), was seen in subjects with EILO before the onset of laryngeal closure; there were however no differences in dyspnea intensity between groups. Using simultaneous measurements of respiratory mechanics and diaphragm electromyography with endoscopic video, we demonstrate, for the first time, increased work of breathing and respiratory neural drive in association with the development of EILO. Future detailed investigations are now needed to understand the role of upper airway closure in causing exertional dyspnea and exercise limitation. NEW & NOTEWORTHY Exercise-induced laryngeal obstruction is a prevalent cause of exertional dyspnea in young individuals; yet, how laryngeal closure affects breathing is unknown. In this study we synchronized endoscopic video with respiratory physiological measurements, thus providing the first detailed commensurate assessment of respiratory mechanics and neural drive in relation to laryngeal closure. Laryngeal closure was associated with increased work of breathing and respiratory neural drive preceded by an augmented tidal volume and a rise in minute ventilation.


Assuntos
Dispneia/etiologia , Exercício Físico/fisiologia , Inalação , Doenças da Laringe/fisiopatologia , Adulto , Estudos de Casos e Controles , Eletromiografia , Feminino , Humanos , Doenças da Laringe/complicações , Laringoscopia , Masculino , Projetos Piloto , Estudos Prospectivos
13.
Thorax ; 72(3): 256-262, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27807016

RESUMO

BACKGROUND: The mechanisms underlying sleep-related hypoventilation in patients with coexisting COPD and obstructive sleep apnoea (OSA), an overlap syndrome, are incompletely understood. We compared neural respiratory drive expressed as diaphragm electromyogram (EMGdi) and ventilation during stage 2 sleep in patients with COPD alone and patients with overlap syndrome. METHODS: EMGdi and airflow were recorded during full polysomnography in 14 healthy subjects, 14 patients with OSA and 39 consecutive patients with COPD. The ratio of tidal volume to EMGdi was measured to indirectly assess upper airway resistance. RESULTS: Thirty-five patients with COPD, 12 healthy subjects and 14 patients with OSA completed the study. Of 35 patients with COPD, 19 had COPD alone (FEV1 38.5%±16.3%) whereas 16 had an overlap syndrome (FEV1 47.5±16.2%, AHI 20.5±14.1 events/hour). Ventilation (VE) was lower during stage 2 sleep than wakefulness in both patients with COPD alone (8.6±2.0 to 6.5±1.5 L/min, p<0.001) and those with overlap syndrome (8.3±2.0 to 6.1±1.8 L/min). Neural respiratory drive from wakefulness to sleep decreased significantly for patients with COPD alone (29.5±13.3% to 23.0±8.9% of maximal, p<0.01) but it changed little in those with overlap syndrome. The ratio of tidal volume to EMGdi was unchanged from wakefulness to sleep in patients with COPD alone and healthy subjects but was significantly reduced in patients with OSA or overlap syndrome (p<0.05). CONCLUSIONS: Stage 2 sleep-related hypoventilation in COPD alone is due to reduction of neural respiratory drive, but in overlap syndrome it is due to increased upper airway resistance.


Assuntos
Diafragma/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/fisiopatologia , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Testes de Função Respiratória , Sistema Respiratório/fisiopatologia , Síndrome
14.
J Proteomics ; 152: 226-235, 2017 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-27871873

RESUMO

The soil-borne necrotrophic pathogen fungus Rhizoctonia solani is destructive, causing disease in various important crops. To date, little is known about the host defence mechanism in response to invasion of R. solani. Here, an iTRAQ-based proteomic analysis was employed to investigate pathogen-responsive proteins in the disease tolerant/resistant cotton cultivar CRI35. A total of 174 differentially accumulated proteins (DAPs) were identified after inoculation of cotton plants with R. solani. Functional categorization analysis indicated that these DAPs can be divided into 12 subclasses. Notably, a large portion of DAPs are known to function in reactive oxygen species (ROS) metabolism and the expression of several histone-modifying and DNA methylating proteins were significantly induced upon challenge with the fungus, indicating that the redox homeostasis and epigenetic regulation are important for cotton defence against the pathogen. Additionally, the expression of proteins involved in phenylpropanoid biosynthesis was markedly changed in response to pathogen invasion, which may reflect a particular contribution of secondary metabolism in protection against the fungal attack in cotton. Together, our results indicate that the defence response of cotton plants to R. solani infection is active and multifaceted and involves the induction of proteins from various innate immunity-related pathways. SIGNIFICANCE: Cotton damping-off is a destructive disease caused by the necrotrophic fungus Rhizoctonia solani. To date, the host defence mechanism involved in the disease protection remains largely unknown. Here, we reported the first proteomic analysis on cotton immune responses against R. solani infection. Employing iTRAQ technique, we obtained a total of 174 differentially accumulated proteins (DAPs) that can be classified into 12 functional groups. Further analysis indicated that ROS homeostasis, epigenetic regulation and phenylpropanoid biosynthesis were tightly associated with the innate immune responses against R. solani infection in cotton. The obtained data provide not only important information for understanding the molecular mechanism involved in plant-R. solani interaction but also application clues for genetic breeding of crops with improved R. solani resistance.


Assuntos
Gossypium/microbiologia , Interações Hospedeiro-Patógeno/imunologia , Doenças das Plantas/microbiologia , Proteômica/métodos , Rhizoctonia/patogenicidade , Epigênese Genética , Imunidade Inata , Oxirredução
15.
Sleep ; 38(6): 941-9, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25669181

RESUMO

STUDY OBJECTIVES: It has been hypothesized that arousals after apnea and hypopnea events in patients with obstructive sleep apnea are triggered when neural respiratory drive exceeds a certain level, but this hypothesis is based on esophageal pressure data, which are dependent on flow and lung volume. We aimed to determine whether a fixed threshold of respiratory drive is responsible for arousal at the termination of apnea and hypopnea using a flow independent technique (esophageal diaphragm electromyography, EMGdi) in patients with obstructive sleep apnea. SETTING: Sleep center of state Key Laboratory of Respiratory Disease. PATIENTS: Seventeen subjects (two women, mean age 53 ± 11 years) with obstructive sleep apnea/hypopnea syndrome were studied. METHODS: We recorded esophageal pressure and EMGdi simultaneously during overnight full polysomnography in all the subjects. MEASUREMENTS AND RESULTS: A total of 709 hypopnea events and 986 apnea events were analyzed. There was wide variation in both esophageal pressure and EMGdi at the end of both apnea and hypopnea events within a subject and stage 2 sleep. The EMGdi at the end of events that terminated with arousal was similar to those which terminated without arousal for both hypopnea events (27.6% ± 13.9%max vs 29.9% ± 15.9%max, P = ns) and apnea events (22.9% ± 11.5%max vs 22.1% ± 12.6%max, P = ns). The Pes at the end of respiratory events terminated with arousal was also similar to those terminated without arousal. There was a small but significant difference in EMGdi at the end of respiratory events between hypopnea and apnea (25.3% ± 14.2%max vs 21.7% ± 13.2%max, P < 0.05]. CONCLUSIONS: Our data do not support the concept that there is threshold of neural respiratory drive that is responsible for arousal in patients with obstructive sleep apnea.


Assuntos
Nível de Alerta , Impulso (Psicologia) , Respiração , Apneia Obstrutiva do Sono/fisiopatologia , Idoso , Diafragma/fisiologia , Eletromiografia , Esôfago/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Pressão , Transtornos Respiratórios/fisiopatologia , Fases do Sono
16.
Pulm Pharmacol Ther ; 30: 51-6, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25449059

RESUMO

BACKGROUND: Studies have shown that tiotropium once daily reduces lung hyperinflation and dyspnea during exercise and improves exercise tolerance in patients with COPD. Mechanisms underlying the effects of the muscarinic receptor antagonist tiotropium on COPD have not been fully understood. OBJECTIVE: In this study, we investigated whether improvement in neural respiratory drive is responsible for reducing dyspnea during exercise and improving exercise tolerance in COPD. METHODS: Twenty subjects with severe COPD were randomized into two groups: no treatment (Control, n = 10, 63.6 ± 4.6 years, FEV1 29.6 ± 13.3%pred) or inhaled tiotropium 18 µg once daily for 1 month (n = 10, 66.5 ± 5.4 years, FEV1 33.0 ± 11.1%pred). All subjects were allowed to continue their daily medications other than anti-cholinergics during the study. Constant cycle exercise with 75% of maximal workload and spirometry were performed before and 1 month after treatment. Diaphragmatic EMG (EMGdi) and respiratory pressures were recorded with multifunctional esophageal catheter. Efficiency of neural respiratory drive, defined as the ratio of minute ventilation (VE) and diaphragmatic EMG (VE/EMGdi%max), was calculated. Modified British Medical Research Council Dyspnea Scale (mMRC) was used for the evaluation of dyspnea before and after treatment. RESULTS: There was no significant difference in spirometry before and after treatment in both groups. Diaphragmatic EMG decreased significantly at rest (28.1 ± 10.9% vs. 22.6 ± 10.7%, P < 0.05) and mean efficiency of neural respiratory drive at the later stage of exercise increased (39.8 ± 2.9 vs. 45.2 ± 3.9, P < 0.01) after 1-month treatment with tiotropium. There were no remarkable changes in resting EMGdi and mean efficiency of neural respiratory drive post-treatment in control group. The score of mMRC decreased significantly (2.5 ± 0.5 vs. 1.9 ± 0.7, P < 0.05) after 1-month treatment with tiotropium, but without significantly difference in control group. CONCLUSION: Tiotropium significantly reduces neural respiratory drive at rest and improves the efficiency of neural respiratory drive during exercise, which might account for the improvement in exercise tolerance in COPD.


Assuntos
Tolerância ao Exercício/efeitos dos fármacos , Antagonistas Muscarínicos/farmacologia , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Derivados da Escopolamina/farmacologia , Idoso , Dispneia/tratamento farmacológico , Dispneia/etiologia , Teste de Esforço , Volume Expiratório Forçado , Humanos , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Índice de Gravidade de Doença , Espirometria , Brometo de Tiotrópio
17.
Yao Xue Xue Bao ; 50(12): 1637-44, 2015 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-27169289

RESUMO

This study was designed to use iTRAQ technology coupled with 2D LC-MS/MS to study the comparative proteomics of different processing technology for pilose antler. 1015 proteins were identified with 2D LC combined with MOLDI TOF/TOF mass spectrometry. Comparative analysis with Protein Pilot (Version 4.5) revealed that 87 proteins were changed (P ≤ 0.05, the ratio of > 1.50 or < 0.60 as the threshold selection of difference proteins), of which 24 were up regulated and 33 were down regulated in the traditional frying process (TFP) compared with the fresh pilose antler (P ≤ 0.05). 7 significant different proteins (P ≤ 0.001), most of these significantly changed proteins were found to be involved in calcium ion binding and ATP binding associated with human healthy. Freeze drying with protective agent (FDP) (Trehalose) can improve the content of significantly different proteins (P ≤ 0.001) including Collagen alpha-1 (XII) chain (COL12A1) and Collagen alpha-1 (II) chain (COL2A1). The significant function involves in platelets activating, maintenance of spermatogonium, and disorder expression in tumor cells. The functional annotation by Hierarchical clustering and GO (gene ontology) showed that the main molecule functions of the proteins significantly changed in these processes were involved in binding (52.7%), catalytic (25.3%), structural molecule and transporter (6.6%).


Assuntos
Chifres de Veado/química , Proteômica , Tecnologia Farmacêutica/métodos , Animais , Cromatografia Líquida , Colágeno/química , Regulação para Baixo , Liofilização , Regulação da Expressão Gênica , Espectrometria de Massas em Tandem , Regulação para Cima
18.
J Biol Chem ; 289(39): 26949-26959, 2014 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-25122768

RESUMO

Conserved clusters of genes encoding DsrE and TusA homologs occur in many archaeal and bacterial sulfur oxidizers. TusA has a well documented function as a sulfurtransferase in tRNA modification and molybdenum cofactor biosynthesis in Escherichia coli, and DsrE is an active site subunit of the DsrEFH complex that is essential for sulfur trafficking in the phototrophic sulfur-oxidizing Allochromatium vinosum. In the acidothermophilic sulfur (S(0))- and tetrathionate (S4O6(2-))-oxidizing Metallosphaera cuprina Ar-4, a dsrE3A-dsrE2B-tusA arrangement is situated immediately between genes encoding dihydrolipoamide dehydrogenase and a heterodisulfide reductase-like complex. In this study, the biochemical features and sulfur transferring abilities of the DsrE2B, DsrE3A, and TusA proteins were investigated. DsrE3A and TusA proved to react with tetrathionate but not with NaSH, glutathione persulfide, polysulfide, thiosulfate, or sulfite. The products were identified as protein-Cys-S-thiosulfonates. DsrE3A was also able to cleave the thiosulfate group from TusA-Cys(18)-S-thiosulfonate. DsrE2B did not react with any of the sulfur compounds tested. DsrE3A and TusA interacted physically with each other and formed a heterocomplex. The cysteine residue (Cys(18)) of TusA is crucial for this interaction. The single cysteine mutants DsrE3A-C(93)S and DsrE3A-C(101)S retained the ability to transfer the thiosulfonate group to TusA. TusA-C(18)S neither reacted with tetrathionate nor was it loaded with thiosulfate with DsrE3A-Cys-S-thiosulfonate as the donor. The transfer of thiosulfate, mediated by a DsrE-like protein and TusA, is unprecedented not only in M. cuprina but also in other sulfur-oxidizing prokaryotes. The results of this study provide new knowledge on oxidative microbial sulfur metabolism.


Assuntos
Proteínas Arqueais/metabolismo , Proteínas de Transporte/metabolismo , Complexos Multiproteicos/metabolismo , Sulfolobaceae/metabolismo , Enxofre/metabolismo , Sulfurtransferases/metabolismo , Substituição de Aminoácidos , Proteínas Arqueais/genética , Proteínas de Transporte/genética , Complexos Multiproteicos/genética , Mutação de Sentido Incorreto , Oxirredução , Homologia de Sequência de Aminoácidos , Sulfolobaceae/genética , Sulfurtransferases/genética
20.
Sleep ; 36(12): 1929-37, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24293768

RESUMO

STUDY OBJECTIVES: To determine the clinical variables that best predict long- term continuous positive airway pressure (CPAP) adherence among patients with cardiovascular disease who have obstructive sleep apnea (OSA). DESIGN: 12-mo prospective within-trial observational study. SETTING: Centers in China, Australia, and New Zealand participating in the Sleep Apnea cardioVascular Endpoints (SAVE) study. PATIENTS: There were 275 patients age 45-70 y with cardiovascular disease (i.e., previously documented transient ischemic attack, stroke, or coronary artery disease) and OSA (4% oxygen desaturation index (ODI) > 12) who were randomized into the CPAP arm of the SAVE trial prior to July 1, 2010. METHODS: Age, sex, country of residence, type of cardiovascular disease, baseline ODI, severity of sleepiness, and Hospital Anxiety and Depression Scale (HADS) scores plus CPAP side effects and adherence at 1 mo were entered in univariate analyses in an attempt to identify factors predictive of CPAP adherence at 12 mo. Variables with P < 0.2 were then included in a multivariate analysis using a linear mixed model with sites as a random effect and 12-mo CPAP use as the dependent outcome variable. MEASUREMENTS AND RESULTS: CPAP adherence at 1, 6, and 12 mo was (mean ± standard deviation) 4.4 ± 2.0, 3.8 ± 2.3, and 3.3 ± 2.4 h/night, respectively. CPAP use at 1 mo (effect estimate ± standard error, 0.65 ± 0.07 per h increase, P < 0.001) and side effects at 1 mo (-0.24 ± 0.092 per additional side effect, P = 0.009) were the only independent predictors of 12- mo CPAP adherence. CONCLUSION: Continuous positive airway pressure use in patients with coexisting cardiovascular disease and moderate to severe obstructive sleep apnea decreases significantly over 12 months. This decline can be predicted by early patient experiences with continuous positive airway pressure (i.e., adherence and side effects at 1 month), raising the possibility that intensive early interventions could improve long-term continuous positive airway pressure compliance in this patient population. CLINICAL TRIALS REGISTER: Clinical Trials, http://www.clinicaltrials.gov, NCT00738179.


Assuntos
Doenças Cardiovasculares/complicações , Pressão Positiva Contínua nas Vias Aéreas/psicologia , Cooperação do Paciente/estatística & dados numéricos , Apneia Obstrutiva do Sono/terapia , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/psicologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...